Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Electric Type |
Still deciding? Get samples of US$ 100/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Ambient air temperature of -5 °C to +40 °C.
2. The altitude of the installation site does not exceed 2000m.
3.The relative humidity of the air at the installation site shall not exceed 50% at a maximum temperature of +40°C, and may be higher at lower temperatures, e.g. up to 90% at 20°C. Special measures shall be taken for occasional condensation due to temperature changes.
4. Pollution class 3.
5.The circuit breaker can withstand mechanical vibration with a frequency of 2Hz~13.2Hz, displacement of ±1mm and a frequency of 13.2Hz~100Hz and acceleration of ±0.7g by IEC60947-2 test requirements.
6.The installation category of the main circuit of the breaker is three categories, and the installation category of the other auxiliary circuits is two categories
7. The circuit breaker is suitable for electromagnetic environment A.
8. The damp heat belt type (TH type) circuit breaker passes the test requirements of GB/T2423.4, GB/T2423.18 and is resistant to the effects of humid air, salt spray, oil mist and mould.
9. The circuit breaker shall be installed in a place where there is no danger of explosion and no conductive dust, or sufficient corrosion of metal and damage to insulation.
10. The circuit breaker shall be installed in a place free from rain and snow.
11.Storage conditions: the surrounding air temperature is -25ºC ~ +70ºC.
Basic Info.
Model |
Rated current (In) |
Poles | Ue | Icu | Ics | Icw | Ui | Uimp | Mechanical Endurance |
Electrical safe life |
Flashover distance mm) |
ARM3E-125M | 16A,20A,25A,32A,40A,45A,50A,55A,60A,63A,65A,70A,80A,85A,90A,95A,100A,125A | 3P | AC400V | 50KA | 35KA | 3kA/1s | 1000V | 8KV | 8500 | 1500 | ≯50 |
ARM3E-125M | 16A,20A,25A,32A,40A,45A,50A,55A,60A,63A,65A,70A,80A,85A,90A,95A,100A,125A | 4P | AC400V | 50KA | 35KA | 1000V | 8KV | 8500 | 1500 | ≯50 | |
ARM3E-125H | 16A,20A,25A,32A,40A,45A,50A,55A,60A,63A,65A,70A,80A,85A,90A,95A,100A,125A | 3P | AC400V | 85KA | 50KA | 1000V | 8KV | 8500 | 1500 | ≯50 | |
ARM3E-125H | 16A,20A,25A,32A,40A,45A,50A,55A,60A,63A,65A,70A,80A,85A,90A,95A,100A,125A | 4P | AC400V | 85KA | 50KA | 1000V | 8KV | 8500 | 1500 | ≯50 |
Mode |
Rated current (In) |
Poles |
Structure size |
Dimensions (W*L*H1) |
Dimensions (W*L*H2) |
ARM3E-125M |
16A,20A,25A,32A,40A,45A,50A,55A,60A,63A,65A,70A,80A,85A,90A,95A,100A,125A |
3P |
|
92*150*110 |
92*150*92 |
ARM3E-125M |
16A,20A,25A,32A,40A,45A,50A,55A,60A,63A,65A,70A,80A,85A,90A,95A,100A,125A |
4P |
122*150*110 |
122*150*92 |
|
ARM3E-125H |
16A,20A,25A,32A,40A,45A,50A,55A,60A,63A,65A,70A,80A,85A,90A,95A,100A,125A |
3P |
92*150*110 |
92*150*92 |
|
ARM3E-125H |
16A,20A,25A,32A,40A,45A,50A,55A,60A,63A,65A,70A,80A,85A,90A,95A,100A,125A |
4P |
122*150*110 |
122*150*92 |
Product Overview
1. ARM3E series moulded case circuit breakers include thermal magnetic type, electronic type and leakage type circuit breakers, they have reinforced BMC base, BMC middle cover and nylon upper cover.
2. ARM3E highlights
The circuit breaker has overload, short circuit and undervoltage protection functions, and can protect lines and power equipment from damage.
1. According to the rated ultimate short-circuit breaking capacity, the circuit breakers are classified into four types: C (economic type), L (standard type), M (medium breaking type) and H (high breaking type).
2. ARXM3E accessories are modularized, safe and reliable, with small volume, high breaking capacity, short flashover, high vibration resistance, etc.
3. The circuit breaker has passed the test requirements of GB/T2423.10 and GB/T2423.18, and can withstand the influence of humid air, salt mist, oil mist and mold
4. The neutral pole type of ARXM3-125~630 is A/B circuit breaker when it is of 4 poles specification, which can have a unique function of "overload alarm without tripping" to ensure the continuity of power supply and meet the requirements of Article 6.3.6 of GB50054.
5. It is required to withstand mechanical vibration with frequency of 2Hz~13.2Hz, displacement of ± 1mm, frequency of 13.2Hz~100Hz and acceleration of ± 0.7g;
3. Material advantages of ARM3E products
One of the material advantages of ARM3E products ---- heat shrinkable insulating materials
The nylon materials such as the upper cover of ARM3E are halogen-free VO flame retardant, high and low temperature resistant, aging resistant high-quality plastics, brand: reinforced flame retardant nylon PA66.
The products have longer electrical life and strength, better appearance and higher breaking capacity.
Engineering plastics are resistant to high and low temperatures, ultraviolet rays, aging resistance, good insulation strength, and good dimensional stability of parts to ensure that the product does not degrade performance in complex working environments;
The second material advantage of ARM3E product---- alloy contact with high silver content: the silver content can reach 95%
1,High silver content, high conductivity, thermal conductivity, arc resistance, electric wear resistance,
2,Preparation of dynamic and static contact material standards and reliable process guarantee, improving the electrical life of circuit breaker by 50%.
The third material advantage of ARM3E product ---- mechanism:
High quality high carbon steel materials, iron base materials of main iron parts (cold rolled steel 10 # steel) , all adopt A+ materials.
High quality low carbon cold rolled steel is used, and after QPQ salt bath composite treatment, the wear resistance, corrosion resistance and fatigue resistance of metal surface are greatly improved, and the strength, mechanical life and electrical life of parts are improved by more than 10%.
Surface treatment and processing technology of mechanism parts: QPQ heat treatment technology imported from Germany.
1. We selected the operating mechanism (steel) of AceReare Electric and another brand sample to compare the experimental results
The operating mechanism of AceReare Electric has a hardness of 366.1, while the hardness of the other brand is only 252.6, which cannot even reach our lowest value.
The mechanical life and electrical life are very important indicators in the national standard of the circuit breaker, and our circuit breaker operating mechanism needs to reach a certain strength and hardness, so that the circuit breaker will not damage the service life of the circuit breaker in the opening and closing process, while the hardness of the other brand is far lower than the national standard.
2. Carburizing test
Surface treatment process, it tests dense compound layer which enhances smoke and abrasion resistance.
Obvious compound layer was detected from the sample of AceReare Electric, while the other brand showed no data.
The fourth material advantage of ARM3E products - thermosetting insulating materials
The unique formula material is adopted, which has high strength, good arc resistance, strong insulation, high temperature resistance and good flame retardancy.
The fifth material advantage of ARM3E product ---- high sensitivity temperature sensor
High quality bimetallic element materials are used, and there is no need to reduce the capacity from -5ºC to 55ºC.
The sixth material advantage of ARM3E products ---- spring materials with longer temperature resistance and fatigue resistance (50% longer than ordinary springs)
4. Product structure of ARM3E thermomagnetic circuit breaker
Safety, it can directly disassemble the upper cover of ARM3E to install internal accessories.
Accessory installation features: humanized design, making installation and replacement more convenient for on-site installation.
5. Usage scenarios of ARM3E moulded case circuit breaker
Outer packaging information (dimensions Weight)
Model number |
Minimum order quantity |
Product size mm (L*W*H) |
Weight |
Packing metho (wooden box/carton) |
Number of boxes |
Inner box size cm (L*W*H) |
Outer box size cm (L*W*H) |
Box weight (g) |
ARM3E-125M-3300 | 50 | 150*92*92 | Cardboard boxe | 16 | 17*11*12.5 | 46cm*26.5cm*35cm | 2750 |
Accessories and Accessories
1.Q: Are you trading company or manufacturer ?
A: We are manufacturer and specializing in manufacturing good quality of MCCB.