Acereare Arm1l Series 4-Pole 630A High Sensitivity Residual Current Circuit Breaker for Enhanced Electrical Safety

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 200/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100000 RMB
Plant Area
>2000 square meters
  • Acereare Arm1l Series 4-Pole 630A High Sensitivity Residual Current Circuit Breaker for Enhanced Electrical Safety
  • Acereare Arm1l Series 4-Pole 630A High Sensitivity Residual Current Circuit Breaker for Enhanced Electrical Safety
  • Acereare Arm1l Series 4-Pole 630A High Sensitivity Residual Current Circuit Breaker for Enhanced Electrical Safety
  • Acereare Arm1l Series 4-Pole 630A High Sensitivity Residual Current Circuit Breaker for Enhanced Electrical Safety
  • Acereare Arm1l Series 4-Pole 630A High Sensitivity Residual Current Circuit Breaker for Enhanced Electrical Safety
  • Acereare Arm1l Series 4-Pole 630A High Sensitivity Residual Current Circuit Breaker for Enhanced Electrical Safety
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • FAQ
Overview

Basic Info.

Model NO.
ARM1L-630M 4P
Arc-extinguishing Medium
Air
Structure
MCCB
Poles Number
4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CCC
Transport Package
Carton
Specification
240*270*150
Trademark
AceRreare/OEM/ODM
Origin
China
HS Code
853620
Production Capacity
500

Product Description

Product Description

Product Overview

Residual current circuit breaker, mainly applicable to AC 50Hz, rated voltage 400V, rated current up to 800A in the distribution network, used to provide indirect contact protection to people, can also be used to prevent fire hazards caused by equipment insulation damage, resulting in ground fault current, and can be used to distribute electrical energy and protect the line and power supply equipment overload and short circuit, but also as the line of infrequent conversion and motor Infrequent switching and motor starting. Conventional leakage protection module with residual current protection circuit breaker work power sampling for two-phase, this series of circuit breakers for three-phase, if the lack of a phase, circuit breaker leakage protection module can still work normally; rated residual action current and maximum disconnection time according to the actual situation on site adjustable; when the phase voltage is reduced to 50V, leakage protection module can still work normally

Envirinment of use

1,The surrounding air temperature state is: -5ºC~+40ºC

2,The altitude of the installation site does not exceed 2000m

3,The relative humidity of the air at the installation site does not exceed 50% at the highest temperature of +40ºC, and can have a higher relative humidity at lower temperatures, such as up to 90% at 20ºC. Special measures should be taken for the occasional condensation due to temperature changes.

4,The pollution level is 3

5, wet and hot band type (TH type) circuit breakers through GB/T2423.4, GB/T2423.18 test requirements, can withstand the effects of humid air, salt spray, oil mist, mold.

6,The circuit breaker should be installed in a place where there is no danger of explosion and no conductive dust, not enough to corrode the metal and destroy the insulation

7, the circuit breaker should be installed in a place where there is no rain or snow intrusion

8,Operating conditions: the circuit breaker passes the test requirements of GB/T 2423.1 and GB/T2423.2, the surrounding air temperature can be as low as -25ºC (ARM1DC/ARM3DC/ARM6DC can provide temperature as low as -40ºC, consult our company), as high as +70ºC (more than 40ºC reduced capacity use, see the technical information in the attached sample)

Product Parameters

Basic Info.

Model Current shell frame

Rated

current

(In)

Use Category Poles Ue Icu Ics  I△n  I△no I△m Ui Uimp Mechanical Endurance

Electrical

safe

lif

Flashover distance

(mm)

ARM1L-630M 630A

400A,500A,630A,

Class A 3P 400V 65KA 42KA 1:100,300,500
2:300,500,1000
 I△n x50% Icu x25% 1000V 8KV 4000 1000 ≯100
ARM1L-630M 630A

400A,500A,630A,

Class A 4P 400V 65KA 42KA 1:100,300,500
2:300,500,1000
 I△n x50% Icu x25% 1000V 8KV 4000 1000 ≯100
ARM1L-630H 630A

400A,500A,630A,

Class A 3P 400V 100KA 70KA 1:100,300,500
2:300,500,1000
 I△n x50% Icu x25% 1000V 8KV 4000 1000 ≯100
ARM1L-630H 630A

400A,500A,630A,

Class A 4P 400V 100KA 70KA 1:100,300,500
2:300,500,1000
 I△n x50% Icu x25% 1000V 8KV 4000 1000 ≯100

 

Model

Rated current (In)

Poles

Structure size

Dimensions(W*L*H1)

Dimensions(W*L*H2)

ARM1L-630M

400A,500A,630A

3P

Acereare Arm1l Series 4-Pole 630A High Sensitivity Residual Current Circuit Breaker for Enhanced Electrical Safety

182*270*150

182*270*110

ARM1L-630M

400A,500A,630A

4P

240*270*150

240*270*110

ARM1L-630H

400A,500A,630A

3P

182*270*150

182*270*110

ARM1L-630H

400A,500A,630A

4P

240*270*150

240*270*110

Detailed Photos

Acereare Arm1l Series 4-Pole 630A High Sensitivity Residual Current Circuit Breaker for Enhanced Electrical Safety

FAQ

1.Q: Are you trading company or manufacturer ?
   A: We are manufacturer and specializing in manufacturing good quality of MCCB.

2.Q: How long is your delivery time?

   A: Normally 5-10 days if there are goods in stock. Or it will take 15-20 days. For customized   items, the delivery time depends.

3.Q: What is your terms of payment ?

   A: 30% T/T in advance ,and the balance before shipment.
 

4.Q : Can you make customized products or packing?
   A: Yes.We can offer customized products and packing ways can be made according to customer's requirement.


5.Q: Can you offer mould making services?
A: We have made many mould for different customers for years.Wecan offer DMC Thermosetting Compressionmoulding
,Thermoplastic injection moulding,Metal stamping moulding.

6.Q: How about the guarantee period?
A: It varies according the different kinds of product. We can negotiate it before place an order.

7.Q: What is your production capacity?
   A: We can produce 3000  sets per month.

8.Q: How about the scale of your factory?
   A: Our total area is 7000 square meter. We have 300staffs, .40 engineers.

9.Q: What tests do you have to confirm the quality of the arc chamber?
   A: We have a incoming inspection for the raw material and process inspection for the rivet and stamping. There is also final statistical audit which consisting the measurement of sizes, tensile test and coat examine.

10.Q: What are the countries you have exported to?

A: We have not worked directly with foreign customers before, we provide ODM and OEM services for brands in China and then they take our products and sell them to foreign customers, basically to Europe and the Middle East.
11,Q: Your products are really good, but we have seen the same circuit breakers on the market nearby and their prices are much cheaper than yours.
A: First of all, I would like to emphasise that the price is definitely proportional to the quality. If you are a buyer, you must know that the materials and treatment processes used in our products are better than those of our peers, and the quality is recognised in the same industry. Our factory has a thermosetting workshop, thermoplastic workshop, welding workshop, hardware stamping workshop and assembly workshop, and the rate of self-made parts is as high as 80%. We have also built a new factory in Wuhu to guarantee the supply of parts for us, so that the parameters and various technical indicators such as mechanical life, Icu, Ics, etc. are very stable, and the match between parts is very high, and the service life of the finished product is also very long, which is They can be used in high-end industrial areas and hospitals, where the quality of the circuit breakers is very high. We also have our own technology patents and a very professional R&D team of 30-40 engineers to respond to the various needs of our customers, the development cycle of new products only takes 30-40 days, in the process, unconditionally provide you with technical expenses, we can greatly reduce the cost of communication and research and development costs. if particularly urgent, I can apply to my superiors to set up a customer line for you, specifically for you to assemble MCCB.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier